Integrated design
Low maintenance volume
Residual or total chlorine monitoring using the classic DPD method
ZMING HQ-1001 Water Quality Monitoring System for Water Supply Network is a multi-parameter online water quality analyzer developed specifically for the online monitoring of water quality in water supply network. It can continuously monitor water quality parameters such as residual chlorine, total chlorine, turbidity, pH, temperature, ORP, conductivity, etc. It can be perfectly applied to secondary water supply, swimming pool water quality monitoring, and other occasions.
Application Fields:
Drinking water network monitoring
Secondary water supply monitoring
Swimming pool water monitoring
Water quality of centralized water supply facilities in rural areas monitoring
Process water monitoring in waterworks
Technical Features:
Ø Integrated design: It adopts an integrated design with a small footprint and supports wall and vertical installation. It can continuously monitor water quality parameters such as residual chlorine, total chlorine, turbidity, pH, temperature, ORP, conductivity, etc
Ø Low maintenance: Specially designed for unmanned applications, with automatic cleaning and automatic sewage discharge. Automatic flow recognition, stop water and measurement. Power outages can be automatically restored. Water and electricity separation design, leakage alarm, adjustable residual chlorine measurement cycle, ensuring adjustable reagent replacement cycle within 1-12 months.
Ø Classic measurement method: DPD classic method is used for residual or total chlorine monitoring, and electrochemical electrodes such as pH, ORP, and conductivity can be configured according to requirements. It can also expand indicators such as TOC and chromaticity
Ø Complete communication functions: RS485 digital output and optional multi-channel 4-20mA output, convenient for users to transmit data to the monitoring center; Multi way relay for early warning output, with free setting of upper and lower warning limits.
Technical Index:
Measurement parameters | Measurement methods | Measurement range | Accuracy |
Residual chlorine/Total chlorine | DPD method | (0-5)mg/L | ± 5% reading |
Turbidity | 90°scattering method | (0-10)NTU | The larger of ± 0.01NTU and 2% reading |
pH | electrode method | (0-14) | ± 0.1 |
Conductivity | electrode method | (0-50000)uS/cm | ± 1% |
ORP | electrode method | (-2000-2000)mV | ± 1mV |
Temperature | thermistor | (0-60)℃ | ± 0.1 ℃ |
Power supply | 220VAC±10%,50/60Hz | ||
Relay outputs | Multiple relay outputs, with the freedom to set corresponding measurement parameters and thresholds. | ||
Digital output | RS485(MODBUS RTU) | ||
Optional analog output | multi-channel 4-20mA analog output channel, optional | ||
Calibration | Turbidity, residual chlorine, pH, conductivity, analog output channel | ||
Interface | Water inlet: 2-point PE quick connect Water outlet: 14mm * 18mm hose | ||
Sample flow range | (0.1-5.0)L/min | ||
Sample temperature | (0-40)℃ | ||
Data storage | Can be set with a (0-60) minute storage cycle and one year of historical data | ||
Size | Length 440 * Height 650 * Thickness 260mm | ||
Consumables | Residual chlorine/total chlorine reagent; PH electrode (replaced once a year); Low turbidity cleaning brush (replace once a year) |
产品资料:泽铭科技-HQ1001.pdf